Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Vox Sang ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38516962

RESUMO

BACKGROUND AND OBJECTIVES: Nucleic acid-amplification testing (NAT) is used for screening blood donations/donors for blood-borne viruses. We reviewed global viral NAT characteristics and NAT-yield confirmatory testing used by blood operators. MATERIALS AND METHODS: NAT characteristics and NAT-yield confirmatory testing used during 2019 was surveyed internationally by the International Society of Blood Transfusion Working Party Transfusion-Transmitted Infectious Diseases. Reported characteristics are presented herein. RESULTS: NAT was mainly performed under government mandate. Human immunodeficiency virus (HIV), hepatitis C virus (HCV) and hepatitis B virus (HBV) NAT was performed on all donors and donation types, while selective testing was reported for West Nile virus, hepatitis E virus (HEV), and Zika virus. Individual donation NAT was used for HIV, HCV and HBV by ~50% of responders, while HEV was screened in mini-pools by 83% of responders performing HEV NAT. Confirmatory testing for NAT-yield samples was generally performed by NAT on a sample from the same donation or by NAT and serology on samples from the same donation and a follow-up sample. CONCLUSION: In the last decade, there has been a trend towards use of smaller pool sizes or individual donation NAT. We captured characteristics of NAT internationally in 2019 and provide insights into confirmatory testing approaches used for NAT-yields, potentially benefitting blood operators seeking to implement NAT.

2.
Vox Sang ; 119(4): 315-325, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38390819

RESUMO

BACKGROUND AND OBJECTIVES: Nucleic acid amplification testing (NAT), in blood services context, is used for the detection of viral and parasite nucleic acids to reduce transfusion-transmitted infections. This project reviewed NAT for screening blood donations globally. MATERIALS AND METHODS: A survey on NAT usage, developed by the International Society of Blood Transfusion Working Party on Transfusion-transmitted Infectious Diseases (ISBT WP-TTID), was distributed through ISBT WP-TTID members. Data were analysed using descriptive statistics. RESULTS: Forty-three responses were received from 32 countries. Increased adoption of blood donation viral screening by NAT was observed over the past decade. NAT-positive donations were detected for all viruses tested in 2019 (proportion of donations positive by NAT were 0.0099% for human immunodeficiency virus [HIV], 0.0063% for hepatitis C virus [HCV], 0.0247% for hepatitis B virus [HBV], 0.0323% for hepatitis E virus [HEV], 0.0014% for West Nile virus [WNV] and 0.00005% for Zika virus [ZIKV]). Globally, over 3100 NAT-positive donations were identified as NAT yield or solely by NAT in 2019 and over 22,000 since the introduction of NAT, with HBV accounting for over half. NAT-positivity rate was higher in first-time donors for all viruses tested except WNV. During 2019, a small number of participants performed NAT for parasites (Trypanosoma cruzi, Babesia spp., Plasmodium spp.). CONCLUSION: This survey captures current use of blood donation NAT globally. There has been increased NAT usage over the last decade. It is clear that NAT contributes to improving blood transfusion safety globally; however, there is a need to overcome economic barriers for regions/countries not performing NAT.


Assuntos
Hepatite B , Ácidos Nucleicos , Reação Transfusional , Infecção por Zika virus , Zika virus , Humanos , Doação de Sangue , Doadores de Sangue , Vírus da Hepatite B/genética , Técnicas de Amplificação de Ácido Nucleico , Hepatite B/diagnóstico
3.
Eur J Neurol ; 31(1): e16030, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37548584

RESUMO

BACKGROUND: Acute hepatitis E virus (HEV) infection has recently emerged as a potential trigger for acute dysimmune neuropathies, but prospective controlled studies are lacking. AIMS: To compare the frequency of concomitant acute HEV infection in patients with neuralgic amyotrophy (NA), Guillain-Barré syndrome (GBS), and Bell's palsy with a matched control population. METHODS: Swiss multicenter, prospective, observational, matched case-control study over 3 years (September 2019-October 2022). Neurological cases with NA, GBS, or Bell's palsy were recruited within 1 month of disease onset. Healthy controls were matched for age, sex, geographical location, and timing of blood collection. Diagnostic criteria for acute hepatitis E were reactive serum anti-HEV IgM and IgG assays (ELISA test) and/or HEV RNA detection in serum by real-time polymerase chain reaction (RT-PCR). RT-PCR was performed on sera to confirm IgM positivity. RESULTS: We included 180 patients (59 GBS, 51 NA, 70 Bell's palsy cases) and corresponding matched controls (blood donors) with median age 51 years for both groups and equal gender distribution. Six IgM+ cases were detected in the NA, two in the GBS, and none in the Bell's palsy group. Two controls were anti-HEV IgM-positive. At disease onset, most cases with acute HEV infection had increased liver enzymes. A moderate association (p = 0.027, Fisher's exact test; Cramér's V = -0.25) was observed only between acute HEV infection and NA. CONCLUSION: This prospective observational study suggests an association between concomitant acute HEV infection and NA, but not with GBS or Bell's palsy.


Assuntos
Paralisia de Bell , Paralisia Facial , Síndrome de Guillain-Barré , Vírus da Hepatite E , Hepatite E , Humanos , Pessoa de Meia-Idade , Vírus da Hepatite E/genética , Hepatite E/complicações , Hepatite E/epidemiologia , Hepatite E/diagnóstico , Estudos de Casos e Controles , Estudos Prospectivos , Paralisia de Bell/complicações , Síndrome de Guillain-Barré/epidemiologia , Anticorpos Anti-Hepatite , Doença Aguda , Imunoglobulina M
4.
Biomedicines ; 11(10)2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37893020

RESUMO

RH1 incompatibility between mother and fetus can cause hemolytic disease of the fetus and newborn. In Switzerland, fetal RHD genotyping from maternal blood has been recommended from gestational age 18 onwards since the year 2020. This facilitates tailored administration of RH immunoglobulin (RHIG) only to RH1 negative women carrying a RH1 positive fetus. Data from 30 months of noninvasive fetal RHD screening is presented. Cell-free DNA was extracted from 7192 plasma samples using a commercial kit, followed by an in-house qPCR to detect RHD exons 5 and 7, in addition to an amplification control. Valid results were obtained from 7072 samples, with 4515 (64%) fetuses typed RHD positive and 2556 (36%) fetuses being RHD negative. A total of 120 samples led to inconclusive results due to the presence of maternal or fetal RHD variants (46%), followed by women being serologically RH1 positive (37%), and technical issues (17%). One sample was typed false positive, possibly due to contamination. No false negative results were observed. We show that unnecessary administration of RHIG can be avoided for more than one third of RH1 negative pregnant women in Switzerland. This reduces the risks of exposure to a blood-derived product and conserves this limited resource to women in actual need.

5.
Microorganisms ; 11(10)2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37894033

RESUMO

From 2014 to 2016, the number of hepatitis E virus (HEV) infections in southern Switzerland increased dramatically and suggested food as a potential infection reservoir. We evaluated the effects of food control measures introduced to limit HEV infections, assessing anti-HEV IgG and IgM rates in blood donors before and after the implementation of food control measures in 2017. From 2012 to 2013, we screened 1283, and from 2017 to 2019, we screened 1447 donors for IgG and IgM antibodies. No statistically significant differences were detected for IgG (32.8% from 2012 to 2013 vs. 31.1% from 2017 to 2019, p = 0.337) or IgM rates (2.0% from 2012 to 2013 vs. 2.8% from 2017 to 2019, p = 0.21). Rural provenience and age > 66 are predictors for positive IgG serology. A total of 5.9% of 303 donors included in both groups lost IgG positivity. We also determined nucleic acid testing (NAT) rates after the introduction of this test in 2018, comparing 49,345 donation results from southern Switzerland with those of 625,559 Swiss donor controls, and only 9 NAT-positive donors were found from 2018 to 2023. The high HEV seroprevalence in southern Switzerland may depend on different food supply chains in rural and urban areas. Local preventive measures probably have a limited impact on blood HEV risk; thus, continuous NAT testing is recommended.

6.
J Pediatr Surg ; 58(12): 2435-2440, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37286412

RESUMO

BACKGROUND: We first utilized and reported on the use of cryoanalgesia for postoperative pain control for Nuss procedure in 2016. We hypothesized that postoperative pain control could be optimized if the intercostal nerve anatomy is better understood. To test this hypothesis, human cadavers were dissected to elucidate the intercostal nerve anatomy. Cryoablation technique was modified. METHODS: Cadaver Study: Adult cadavers were used to visualize the branching patterns of the intercostal nerves. Cryoablation: Posterior to the mid-axillary line for intercostal nerves 4, 5, 6 and 7, main intercostal nerve, lateral cutaneous branch and collateral branch were cryoablated under thoracoscopic view. Verbal pain scores were obtained from patients one day after the procedure. RESULTS: The study results were obtained during the years 2021 and 2022. Eleven cadavers were dissected. The path of the main intercostal and lateral cutaneous branch lie on the inferior rib surface of the corresponding intercostal nerve. Total of 92 lateral cutaneous branches of the intercostal nerve were dissected and measured as they pierced the intercostal muscle. Most lateral cutaneous branches of the intercostal nerve pierced the intercostal muscle anterior to midaxillary line 78.3%, posterior to midaxillary line 18.5% or on the midaxillary line 3.3%. The collateral branch of the intercostal nerve separated near the spine and traveled along the superior surface of the next inferior rib. Cryoablation: 22 male patients underwent Nuss procedure with cryoanalgesia. Median age of the patients was 15 years (IQR: 2), median Haller index was 3.73 (IQR: 0.85), median pain score (0-10 maximum pain) was 1 (IQR: 1.75). CONCLUSION: Cryoablation of the intercostal nerve and its two branches improves pain control after a Nuss procedure. LEVEL OF EVIDENCE: Level 4. TYPE OF STUDY: Observational study.


Assuntos
Criocirurgia , Tórax em Funil , Bloqueio Nervoso , Adulto , Humanos , Masculino , Pré-Escolar , Nervos Intercostais/cirurgia , Criocirurgia/métodos , Tórax em Funil/cirurgia , Dor Pós-Operatória , Estudos Retrospectivos , Cadáver
7.
J Med Virol ; 95(7): e28904, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37386901

RESUMO

In a COVID-19 sero-surveillance cohort study with predominantly healthy and vaccinated individuals, the objectives were (i) to investigate longitudinally the factors associated with the quantitative dynamics of antispike (anti-S1) IgG antibody levels, (ii) to evaluate whether the levels were associated with protection from SARS-CoV-2 infection, and (iii) to assess whether the association was different in the pre-Omicron compared with the Omicron period. The QuantiVac Euroimmun ELISA test was used to quantify anti-S1 IgG levels. The entire study period (16 months), the 11-month pre-Omicron period and the cross-sectional analysis before the Omicron surge included 3219, 2310, and 895 reactive serum samples from 949, 919, and 895 individuals, respectively. Mixed-effect linear, mixed-effect time-to-event, and logistic regression models were used to achieve the objectives. Age and time since infection or vaccination were the only factors associated with a decline of anti-S1 IgG levels. Higher antibody levels were significantly associated with protection from SARS-CoV-2 infection (0.89, 95% confidence interval [CI] 0.82-0.97), and the association was higher during the time period when Omicron was predominantly circulating compared with the ones when Alpha and Delta variants were predominant (adjusted hazard ratio for interaction 0.66, 95% CI 0.53-0.84). In a prediction model, it was estimated that >8000 BAU/mL anti-S1 IgG was required to reduce the risk of infection with Omicron variants by approximately 20%-30% for 90 days. Though, such high levels were only found in 1.9% of the samples before the Omicron surge, and they were not durable for 3 months. Anti-S1 IgG antibody levels are statistically associated with protection from SARS-CoV-2 infection. However, the prediction impact of the antibody level findings on infection protection is limited.


Assuntos
COVID-19 , Imunoglobulina G , Humanos , Estudos Longitudinais , Estudos de Coortes , Estudos Transversais , Polícia , SARS-CoV-2
8.
Sports Health ; 15(1): 142-147, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35354392

RESUMO

STUDY DESIGN: Case series. LEVEL OF EVIDENCE: Level 4C.


Assuntos
Lacerações , Esqui , Humanos , Pesquisa
9.
Blood Transfus ; 21(2): 100-109, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35969138

RESUMO

BACKGROUND: Disease morbidity of tick-borne encephalitis (TBE) has been increasing over the last decades. Since the 1990s, however, no extensive seroprevalence studies on TBE in humans have been performed in Switzerland. Here we assessed the prevalence of anti-TBE virus (TBEV) antibodies among different groups of the Swiss blood donor population. MATERIALS AND METHODS: The study was carried out from July 2014 to January 2015. Blood donors participating in the study (n=9,328) were asked to fill in a questionnaire relating to vaccination against or infection with different flaviviruses, and blood samples were collected. All samples were screened for the presence of anti-TBEV IgG antibodies using ELISA testing. Seropositivity rates in different groups of blood donors were compared using Chi square tests with Bonferroni correction. RESULTS: In 2014 and 2015, 24.6% of healthy Swiss blood donors indicated vaccination against TBE. Among vaccinated blood donors, antibody prevalence was significantly higher in younger (<40y: 85.3%) than older individuals (≥40 to <55y: 80.0%, ≥55y: 76.7%; p=0.005). In non-vaccinated individuals, antibody prevalence was significantly higher in younger (<40y: 10.0%) than older (≥40 to <55y: 4.0%, ≥55y: 3.9%; p<0.005), male (6.8%) than female (3.7%, p<0.0001), and blood donors from endemic (7.0%) than border (6.2%) or non-endemic regions (4.2%, p<0.001). Possible asymptomatic infection, as defined by positive IgG ELISA results in blood donors indicating no vaccination against TBEV, was found in 5.6%. DISCUSSION: Our data importantly complement the knowledge on TBEV vaccination rates and estimate the frequency of subclinical TBE in Switzerland.


Assuntos
Vírus da Encefalite Transmitidos por Carrapatos , Encefalite Transmitida por Carrapatos , Humanos , Masculino , Feminino , Doadores de Sangue , Suíça/epidemiologia , Prevalência , Estudos Soroepidemiológicos , Anticorpos Antivirais , Encefalite Transmitida por Carrapatos/epidemiologia , Encefalite Transmitida por Carrapatos/prevenção & controle , Imunoglobulina G
10.
Viruses ; 14(12)2022 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-36560615

RESUMO

During the last few decades, efforts to increase the safety of blood and blood products have mainly focused on preventing the viral infections HCV, HIV, HBV and Treponema pallidum. The evolution of these approaches and the achieved increase in safety is shown for the last 25 years in Switzerland. In detail, the prevalences and incidences of the infection disease and the theoretical estimated residual risks (RR) of these blood-borne infections are presented. Prevalences, incidences and, in particular, the RR have decreased considerably over the last 25 years. This was achieved primarily by the adoption of strict criteria for the selection of blood donors, refined questionnaires, the introduction of increasingly sensitive serological screening tests and the implementation of nucleic acid testing (NAT) for these blood-borne pathogens. These NAT assays have significantly shortened the window period between infection and the first detection of the infectious agent in the blood of an infected individual. A form of "real life" comparison or confirmation is provided by the reported lookback procedures (LBP) and the haemovigilance data of the Swiss competent authority, Swissmedic. These data are in agreement, and thus support the very low prevalences, incidences and RR.


Assuntos
Infecções por HIV , Hepatite C , Humanos , Vírus da Hepatite B/genética , Segurança do Sangue , Treponema pallidum/genética , Suíça/epidemiologia , Programas de Rastreamento/métodos , Infecções por HIV/prevenção & controle , Hepatite C/epidemiologia , Doadores de Sangue , Técnicas de Amplificação de Ácido Nucleico
11.
Transfus Med Hemother ; 49(4): 205-217, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36159954

RESUMO

Background: Malaria is a mosquito-borne infectious disease caused by protozoan parasites of the genus Plasmodium. These parasites can be transmitted by blood transfusion especially through Red Cell Blood Concentrates collected from asymptomatic and parasitemic donors. As migration of populations from endemic areas to Europe and overseas recreational travel to endemic regions increase, there is growing risk of transfusion-transmitted malaria (TTM) in nonendemic regions of the world. The present work provides an overview of the mitigation strategies in nonendemic countries and their effectiveness and discusses possible approaches to evolve the strategies in order to maintain both a safe and adequate blood supply. Summary: The historical and current situation of malaria and TTM in Europe and on the North American continent are described. The infectivity of Plasmodium in blood components and the consequences of TTM are presented, along with the regulations and guidelines for TTM mitigation in Europe, USA, and Canada. The regulations/guidelines currently in place in Europe allow a certain amount of leeway for local policies. A questionnaire was used to survey European countries regarding their current strategies and recent TTM cases. From the questionnaire and published cases, approximately 20 cases of TTM were identified in the past 20 years in the USA and Europe. The vast majority of implicated donors have been former residents of malaria-endemic areas, particularly former residents of hyperendemic areas in Africa. The most recent TTM cases are discussed in detail to provide insight into the gaps in current strategies. The utility and uncertainties of pathogen reduction and serological and molecular testing methods are discussed. Key Messages: Overall, the risk of transfusion-associated malaria in nonendemic countries is considered to be low and very few TTM cases occurred in these regions in the last 20 years. The questionnaire-based strategy with questions about risk in relation to malaria exposure with or without selective testing based on questioning seems to be relatively effective, although rare and sometimes fatal transmissions still occur. An outstanding question is whether in the future molecular methods may further improve the safety of blood products and help constrain the loss of donors.

12.
Immun Inflamm Dis ; 10(7): e640, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35759237

RESUMO

INTRODUCTION: To assess the risk for COVID-19 of police officers, we are studying the seroprevalence in a cohort. The baseline cross-sectional investigation was performed before a vaccination campaign in January/February 2021, and demonstrated a seroprevalence of 12.9%. Here, we demonstrate serosurveillance results after a vaccination campaign. METHODS: The cohort consists of 1022 study participants. The 3- and 6-month follow-up visits were performed in April/May and September 2021. Data on infection and vaccination rates were obtained via measuring antibodies to the nucleocapsid protein and spike protein and online questionnaires. RESULTS: The mean age of the population was 41 (SD 8.8) years, 72% were male and 76% had no comorbidity. Seroconversion was identified in 1.05% of the study population at the 3-month visit and in 0.73% at the 6-month visit, resulting in an infection rate of 1.8% over a time period of 6 months. In comparison, the infection rate in the general population over the same time period was higher (3.18%, p = .018). At the 6-month visit, 77.8% of participants reported being vaccinated once and 70.5% twice; 81% had an anti-S antibody titer of >250 U/ml and 87.1% of ≥2 U/ml. No significant association between infection and job role within the department, working region, or years of experience in the job was found. Anti-spike antibody titers of vaccinated study participants showed a calculated decreasing trend 150-200 days after the second vaccine dose. CONCLUSION: These data confirm the value of the vaccination campaign in an exposed group other than healthcare professionals.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Adulto , COVID-19/epidemiologia , COVID-19/prevenção & controle , Estudos Transversais , Feminino , Humanos , Masculino , Polícia , Estudos Soroepidemiológicos , Suíça/epidemiologia
13.
J Cancer Res Clin Oncol ; 148(3): 647-656, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34874490

RESUMO

PURPOSE: Immune checkpoint inhibitor (ICI)-induced hepatitis belongs to the frequently occurring immune-related adverse events (irAEs), particularly with the combination therapy involving ipilimumab and nivolumab. However, predisposing factors predicting the occurrence of ICI-induced hepatitis are barely known. We investigated the association of preexisting autoantibodies in the development of ICI-induced hepatitis in a prospective cohort of cancer patients. METHODS: Data from a prospective biomarker cohort comprising melanoma and non-small cell lung cancer (NSCLC) patients were used to analyze the incidence of ICI-induced hepatitis, putatively associated factors, and outcome. RESULTS: 40 patients with melanoma and 91 patients with NSCLC received ICI between July 2016 and May 2019. 11 patients developed ICI-induced hepatitis (8.4%). Prior to treatment, 45.5% of patients in the hepatitis cohort and 43.8% of the control cohort showed elevated titers of autoantibodies commonly associated with autoimmune liver diseases (p = 0.82). We found two nominally significant associations between the occurrence of ICI-induced hepatitis and HLA alleles associated with autoimmune liver diseases among NSCLC patients. Of note, significantly more patients with ICI-induced hepatitis developed additional irAEs in other organs (p = 0.0001). Neither overall nor progression-free survival was affected in the hepatitis group. CONCLUSION: We found nominally significant associations of ICI-induced hepatitis with two HLA alleles. ICI-induced hepatitis showed no correlation with liver-specific autoantibodies, but frequently co-occurred with irAEs affecting other organs. Unlike other irAEs, ICI-induced hepatitis is not associated with a better prognosis.


Assuntos
Autoanticorpos/imunologia , Biomarcadores Tumorais/imunologia , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Hepatite/epidemiologia , Inibidores de Checkpoint Imunológico/efeitos adversos , Neoplasias Pulmonares/tratamento farmacológico , Melanoma/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Autoanticorpos/sangue , Biomarcadores Tumorais/sangue , Carcinoma Pulmonar de Células não Pequenas/imunologia , Carcinoma Pulmonar de Células não Pequenas/patologia , Estudos de Casos e Controles , Feminino , Seguimentos , Hepatite/sangue , Hepatite/etiologia , Hepatite/imunologia , Humanos , Neoplasias Pulmonares/imunologia , Neoplasias Pulmonares/patologia , Masculino , Melanoma/imunologia , Melanoma/patologia , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Taxa de Sobrevida , Suíça/epidemiologia
14.
Open Forum Infect Dis ; 8(12): ofab524, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34888394

RESUMO

BACKGROUND: Protests and police fieldwork provide a high-exposure environment for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections. In this cross-sectional analysis, we investigated the seroprevalence among a police cohort, and sociodemographic, work, and health-related factors associated with seropositivity. METHODS: Study participants were invited for serological testing of SARS-CoV-2 and to complete online questionnaires. Serum neutralization titers toward the wild-type SARS-CoV-2 spike protein (expressing D614G) and the Alpha and Beta variants were measured in seropositive study participants. RESULTS: A total of 978 police personnel representing 35% of the entire staff participated from February to March 2021. The seroprevalence was 12.9%. It varied by geographic region, ranged from 9% to 13.5% in 3 regions, including the city; and was 22% in Bernese Seeland/Jura with higher odds for seropositivity (odds ratio [OR], 2.38 [95% confidence interval {CI}, 1.28-4.44], P=.006). Job roles with mainly office activity were associated with a lower risk of seropositivity (OR, 0.33 [95% CI, .14-.77], P=.010). Self-reported compliance with mask wearing during working hours was 100%; 45% of seropositive vs 5% of seronegative participants (P<.001) reported having had contact with a proven coronavirus disease 2019 (COVID-19) case living in the same household prior to serological testing. The level of serum antibody titers correlated with neutralization capacity. Antibodies derived from natural SARS-CoV-2 infection effectively neutralized the SARS-CoV-2 spike protein, but were less effective against the Alpha and Beta variants. CONCLUSIONS: The seroprevalence of anti-SARS-CoV-2 antibodies of police officers was comparable to that reported in the general population, suggesting that the personal protective equipment of the police is effective, and that household contacts are the leading transmission venues. The level of serum antibody titers, in particular that of anti-spike antibodies, correlated well with neutralization capacity. Low antibody titers acquired from natural infection were not effective against variants. CLINICAL TRIALS REGISTRATION: NCT04643444.

15.
Transfus Med Hemother ; 48(5): 265-271, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34803570

RESUMO

BACKGROUND: Malaria is a mosquito-borne infectious disease caused by protozoan parasites of the genus Plasmodium. As migration of populations from endemic areas to Europe and overseas recreational travel to endemic regions increase, there is also a growing risk of transfusion-transmitted tropical diseases by blood components. MATERIAL AND METHODS: In the present study two routine Plasmodium spp. ELISA (CAPTIA™ Malaria EIA, Trinity Biotech, and Malaria EIA, BioRad) were compared with a new commercial ELISA (ELISA IgG, EUROIMMUN). From December 1, 2015 until November 30, 2016, 1,096 plasma samples from blood donors with a potential risk of malaria infection were collected at two blood transfusion centres in Germany and Switzerland. RESULTS: The samples were tested comparatively with the ELISA from EUROIMMUN and the routine test used at the respective centre. Thirty-four of 595 (5.7%) tested blood samples from centre 1 and 49 of 501 (9.8%) tested blood samples from centre 2 showed reactivity on either or both ELISAs. All 83 reactive samples were sent for confirmation to the Diagnostic Centre of the Swiss Tropical and Public Health Institute (Swiss TPH) in Basel, Switzerland. Sixteen samples, which previously were reactive in the routine Plasmodium spp. EIA assays, were proven positive after confirmation testing (i.e., 4 positive and 12 inconclusive results), indicating an anti-Plasmodium antibody prevalence in blood donations of 1.5%. From these 16 reactive samples, 13 were also detected by the index test, resulting in an assay sensitivity of 81.2%. A specificity of 98.6% was calculated (1,065/1,080 confirmed negative samples). The overall agreement with the reference centre was 95.8% in centre 1 and 94% in centre 2. CONCLUSION: The comparison of the new EUROIMMUN ELISA and the established CAPTIA™ Malaria EIA (Trinity Biotech) and Malaria EIA (BioRad) used for routine blood donor screening in two laboratory blood donation centres revealed that all tested ELISAs show comparable sensitivities and are equally suitable for anti-Plasmodium antibody screening in blood banks.

16.
J Virol Methods ; 297: 114271, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34461153

RESUMO

The Elecsys® Anti-SARS-CoV-2 S immunoassay (Roche Diagnostics International Ltd, Rotkreuz, Switzerland) has been developed for the detection of antibodies to the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike (S) protein. We evaluated the assay performance using samples from seven sites in Germany, Austria, and Switzerland. For specificity and sensitivity analyses, 7880 presumed negative pre-pandemic samples and 827 SARS-CoV-2 PCR-confirmed single or sequential samples from 272 different patients were tested, respectively. The overall specificity and sensitivity (≥14 days post-PCR) for the Elecsys Anti-SARS-CoV-2 S immunoassay were 99.95% (95% confidence interval [CI]: 99.87-99.99; 7876/7880) and 97.92% (95% CI: 95.21-99.32; 235/240), respectively. The Elecsys Anti-SARS-CoV-2 S immunoassay had significantly higher specificity compared with the LIAISON® SARS-CoV-2 S1/S2 IgG (99.95% [2032/2033] vs 98.82% [2009/2033]), ADVIA Centaur® SARS-CoV-2 Total (100% [928/928] vs 86.96% [807/928]), ARCHITECT SARS-CoV-2 IgG (99.97% [2931/2932] vs 99.69% [2923/2932]), iFlash-SARS-CoV-2 IgM (100.00% [928/928] vs 99.57% [924/928]), and EUROIMMUN Anti-SARS-CoV-2 IgG (100.00% [903/903] vs 97.45% [880/903]) and IgA (100.00% [895/895] vs 95.75% [857/895]) assays. The Elecsys Anti-SARS-CoV-2 S immunoassay had significantly higher sensitivity (≥14 days post-PCR) compared with the ARCHITECT SARS-CoV-2 IgG (98.70% [76/77] vs 87.01% [67/77]), iFlash-SARS-CoV-2 IgG (100.00% [76/76] vs 93.42% [71/76]) and IgM (100.00% [76/76] vs 35.53% [27/76]), and EUROIMMUN Anti-SARS-CoV-2 IgG (98.26% [113/115] vs 93.91% [108/115]) assays. Therefore, the Elecsys Anti-SARS-CoV-2 S assay demonstrated a reliable performance across various sample populations for the detection of anti-S antibodies.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Humanos , Imunoensaio , Sensibilidade e Especificidade
17.
Infect Dis Ther ; 10(4): 2381-2397, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34368915

RESUMO

INTRODUCTION: We performed a multicentre evaluation of the Elecsys® Anti-SARS-CoV-2 immunoassay (Roche Diagnostics), an assay utilising a recombinant protein representing the nucleocapsid (N) antigen, for the in vitro qualitative detection of antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). METHODS: Specificity was evaluated using serum/plasma samples from blood donors and routine diagnostic specimens collected before September 2019 (i.e., presumed negative for SARS-CoV-2-specific antibodies); sensitivity was evaluated using samples from patients with polymerase chain reaction (PCR)-confirmed SARS-CoV-2 infection. Point estimates and 95% confidence intervals (CIs) were calculated. Method comparison was performed versus commercially available assays. RESULTS: Overall specificity for the Elecsys Anti-SARS-CoV-2 immunoassay (n = 9575) was 99.85% (95% CI 99.75-99.92): blood donors (n = 6714; 99.82%), routine diagnostic specimens (n = 2861; 99.93%), pregnant women (n = 2256; 99.91%), paediatric samples (n = 205; 100.00%). The Elecsys Anti-SARS-CoV-2 immunoassay demonstrated significantly higher specificity versus LIAISON SARS-CoV-2 S1/S2 IgG (99.71% vs. 98.48%), EUROIMMUN Anti-SARS-CoV-2 IgG (100.00% vs. 94.87%), ADVIA Centaur SARS-CoV-2 Total (100.00% vs. 87.32%) and iFlash SARS-CoV-2 IgM (100.00% vs. 99.58%) assays, and comparable specificity to ARCHITECT SARS-CoV-2 IgG (99.75% vs. 99.65%) and iFlash SARS-CoV-2 IgG (100.00% vs. 100.00%) assays. Overall sensitivity for Elecsys Anti-SARS-CoV-2 immunoassay samples drawn at least 14 days post-PCR confirmation (n = 219) was 93.61% (95% CI 89.51-96.46). No statistically significant differences in sensitivity were observed between the Elecsys Anti-SARS-CoV-2 immunoassay versus EUROIMMUN Anti-SARS-CoV-2 IgG (90.32% vs. 95.16%) and ARCHITECT SARS-CoV-2 IgG (84.81% vs. 87.34%) assays. The Elecsys Anti-SARS-CoV-2 immunoassay showed significantly lower sensitivity versus ADVIA Centaur SARS-CoV-2 Total (85.19% vs. 95.06%) and iFlash SARS-CoV-2 IgG (86.25% vs. 93.75%) assays, but significantly higher sensitivity versus the iFlash SARS-CoV-2 IgM assay (86.25% vs. 33.75%). CONCLUSION: The Elecsys Anti-SARS-CoV-2 immunoassay demonstrated very high specificity and high sensitivity in samples collected at least 14 days post-PCR confirmation of SARS-CoV-2 infection, supporting its use to aid in determination of previous exposure to SARS-CoV-2.

18.
Sci Rep ; 10(1): 14219, 2020 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-32848185

RESUMO

We investigated whether intravenous iron supplementation improves fatigue and general health in non-anemic repeat adult blood donors with iron deficiency (ferritin ≤ 50 µg/L). Of 1,487 potentially eligible participants, 203 were randomly assigned to a single intravenous dose of 800 mg iron-carboxymaltose and 202 to placebo; 393 participants completed the trial. At 6 to 8 weeks after intervention, self-rated mean fatigue scores (numeric rating scale from 1-10, primary outcome) were 3.9 ± 1.8 in the iron supplementation group and 4.0 ± 2.2 in the placebo group, showing no group difference (p = 0.819). Pre-specified subgroup analyses of gender, ferritin < 25 µg/L and fatigue ≥ 4 points, as well as exploratory analyses of lower ferritin cut-offs did not reveal any between-group differences. In terms of secondary outcomes, the mean differences were 114.2 µg/L for ferritin (95% CI 103.1-125.3) and 5.7 g/L for hemoglobin (95% CI 4.3-7.2) with significantly higher values in the iron supplementation group. No group differences were observed for different measures of general well-being and other clinical and safety outcomes. Intravenous iron supplementation compared with placebo resulted in increase of ferritin and hemoglobin levels in repeat blood donors with low iron stores, yet had no effect on fatigue and general well-being.


Assuntos
Fadiga/tratamento farmacológico , Compostos Férricos/administração & dosagem , Deficiências de Ferro , Maltose/análogos & derivados , Administração Intravenosa , Adulto , Feminino , Humanos , Masculino , Maltose/administração & dosagem , Pessoa de Meia-Idade , Resultado do Tratamento
19.
Blood Transfus ; 18(6): 446-453, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32203012

RESUMO

BACKGROUND: Nowadays, most blood products are leukocyte-reduced. After this procedure, the residual risk for transfusion transmitted cytomegalovirus (TT-CMV) is mostly attributed to cell-free viruses in the plasma of blood donors following primary infection or viral reactivation. Here, objectives are: 1) to study the behaviour of cell-free CMV through the blood component processing; 2) to determine the anti-CMV seroprevalence, the level of viremia, the window-period in blood donor population; and 3) to identify cases of TT-CMV in bone marrow transplant (BMT) recipients. MATERIALS AND METHODS: Cell-free CMV was injected into blood bags originating from regular donors. Blood components were processed according to either the CompoSelect® or the CompoFlow® (Fresenius Kabi AG) techniques. Samples were analysed at each step for presence of virus DNA using quantitative polymerase chain reaction (PCR). The anti-CMV seroprevalence in our donor population was taken from our donor data system. The viremia was assessed in pooled plasmas samples from routine donations by quantitative PCR. Medical charts of 165 BMT anti-CMV seronegative recipients/anti-CMV seronegative donors who received CMV-unscreened blood products were reviewed. RESULTS: Cell-free CMV passes without any decrease in viral load through all stages of blood processing. The anti-CMV seroprevalence was 46.13%. Four DNA positive samples out of 42,240 individual blood donations were identified (0.009%); all had low levels of viremia (range 11-255 IU/mL). No window-period donation was identified. No TT-CMV was found. DISCUSSION: Cell-free CMV remains a concern with current blood component processing as it passes through all the processes. However, since low levels of CMV DNA were identified in the donations tested, and no BMT recipients had TT-CMV, the residual threat of TT-CMV after leukocyte reduction appears to be very low.


Assuntos
Transfusão de Componentes Sanguíneos/efeitos adversos , Doadores de Sangue , Segurança do Sangue , Infecções Transmitidas por Sangue/epidemiologia , Sangue/virologia , Infecções por Citomegalovirus/transmissão , Citomegalovirus/isolamento & purificação , Reação Transfusional/epidemiologia , Viremia/transmissão , Adulto , Anticorpos Antivirais/sangue , Preservação de Sangue , Coleta de Amostras Sanguíneas/instrumentação , Coleta de Amostras Sanguíneas/métodos , Infecções Transmitidas por Sangue/prevenção & controle , Infecções Transmitidas por Sangue/virologia , Medula Óssea/virologia , Transplante de Medula Óssea/efeitos adversos , Citomegalovirus/imunologia , Infecções por Citomegalovirus/sangue , Infecções por Citomegalovirus/epidemiologia , Infecções por Citomegalovirus/prevenção & controle , DNA Viral/sangue , Humanos , Plasma/virologia , Reação em Cadeia da Polimerase , Estudos Soroepidemiológicos , Suíça/epidemiologia , Reação Transfusional/prevenção & controle , Reação Transfusional/virologia , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...